Description
(1:1 Phase) | ||
MODEL | 2300HS / 2300HS-L | |
CAPACITY (VA Rating) | 3.0 KVA | |
INPUT | Voltage | Single Phase, 110Vac~ 290Vac |
Frequency | 50 Hz (60 Hz on request) ± 5% | |
Power factor | > 0.98% (full load) | |
OUTPUT | Voltage | 220Vac |
Voltage Regulation | 220Vac ± 0.5% | |
Transient Response | ± 3~4% under full load, change and corrected within 2 ms | |
Wave form | Pure Sinewave THD<3% | |
Power factor | 0.8 | |
Frequency | 50 / 60Hz, ± 0.5% | |
Crest Factor | 3:1 | |
Overload | Continuous alarming, switch to bypass, auto recovery upon removing of load | |
Overload Capacity | <110% load Continuous | |
110-125% load 12 Minutes | ||
125-150% load 10 Minutes | ||
>150% load: by pass | ||
Battery | Battery Type | Maintenance free lead-acid batteries |
DC Voltage | 96VDC | |
Backup time | 15-30 minutes depending on load | |
External Battery | Up to 8 hours long time backup depends on external battery | |
Supplementary Charger | Optional 200W/500W charger for extended back-up application | |
Recharge time | 5~8 hours | |
Cold Start | Yes, UPS cab be started without AC source | |
Battery Cabinet | Internal Battery (External Battery back is optional) | |
TRANSFER TIME | Zero (0) millisecond, Inverter to Bypass (Overload) | |
PROTECTIONS | High Voltage, Overload, Overheating, bypass, Short circuit, Noise Filtering, Spike, Surge | |
EMI FILTER | 10~100 KHz at 40dB, 100KHz~100MHz at 70Db | |
ALARM | Audio alarm | Keep 90 seconds at a time interval of 4 seconds |
Battery Low | Auto shutdown upon complete discharge of battery and auto tum-on upon recovery of utility power | |
Fault | Continuous alarming | |
INTERFACE | RS232 / SNMP | |
SOFTWARE MANGEMENT | AC fault, low battery, intelligent software for shutdown by remote control | |
TRONSFORMER TYPE | Built-in Galvanic Isolation Transformer | |
General | Dimensions (mm) | 485x450x190 |
Weight (KG) | 40 / 19 | |
OPERATING ENVIRONMENT | Temperature | 0 ~ 40°C (32 – 104°F) |
Humidity | 30 ~ 90% non-condensing | |
Attitude | <1500M above sea level | |
Audio noise | <53dB-65dB at 1 meter distance |
Description
Apollo 3kVA Online UPS
Apollo 3kVA Online UPS comes with Single Phase input power: from 110Vac ~ 290Vac, DSP control technology with input power factor of >0.98% (Full Load). The Apollo series UPS are providing high performance power supply systems with Single Phase input and Single Phase output and galvanic isolation by high performance inverter output transformer designed to supply high-quality power on a permanent basis. In this Online UPS advanced diagnostics and unit information allow users to monitor system parameters and alarms, check the status of the battery and provide access to the history of events through the system software or multi-language screen. This new Apollo series Online UPS features with On-line UPS double conversion, Single Phase, input/ Single Phase output, DSP control technology, Galvanic insulation by output transformer, Reduced harmonic distortion, RFI filter, Acoustic and luminous signalling. This UPS Reduced harmonic distortion of output signal. This Online UPS also comes with High efficiency, Output power factor 0.8 ~1 (lagging), Software included for System Monitoring. In this online UPS, the Extended battery options available.